![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2608](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452608.webp)
14 QPSK EVM Measurement
View/Display
Press Change Title to enter a new title through the alpha editor. Press Enter or Return to complete the
entry. Press ESC to cancel the entry and preserve your existing title.
The display title will replace the measurement name. It remains for this measurement until you press
Change Title again, or you recall a state, or a Preset is performed. A title can also be cleared by pressing
Title, Clear Title.
Notice the inclusion of the <measurement> parameter in the command below. Because each
measurement remembers the Display Title, the command must be qualified with the measurement name.
For the Swept SA measurement this is not the case; no <measurement> parameter is used when changing
the Display Title for the Swept SA measurement.
Key Path
View/Display, Display, Title
Mode
All
Remote Command
:DISPlay:<measurement>:ANNotation:TITLe:DATA <string>
:DISPlay:<measurement>:ANNotation:TITLe:DATA?
Example
DISP:ANN:TITL:DATA "This Is My Title"
This example is for the Swept SA measurement in the Spectrum Analyzer mode. The SANalyzer
<measurement> name is not used.
DISP:ACP:ANN:TITL:DATA "This Is My Title"
This example is for Measurements other than Swept SA.
Both set the title to: This Is My Title
Notes
Pressing this key cancels any active function.
When a title is edited the previous title remains intact (it is not cleared) and the cursor goes at the
end so that characters can be added or BKSP can be used to go back over previous characters.
Preset
No title (measurement name instead)
State Saved
Saved in instrument state.
Initial S/W Revision
Prior to A.02.00
Clear Title
Clears a title from the front-panel display. Once cleared, the title cannot be retrieved. After the title is
cleared, the current Measurement Name replaces it in the title bar.
Key Path
View/Display, Display, Title
Example
The following commands clear the title and restore the measurement’s original title:
DISP:ANN:TITL:DATA ""
This example is for the Swept SA measurement in the Spectrum Analyzer mode. The SANalyzer
<measurement> name is not used.
DISP:ACP:ANN:TITL:DATA ""
This example is for ACP; in measurements other than Swept SA the measurement name is required.
Notes
Uses the :DISPlay:<measurement>:ANNotation:TITLe:DATA <string> command with an empty string
(in the Swept SA, the <measurement> is omitted).
Preset
Performed on Preset.
Initial S/W Revision
Prior to A.02.00
2608
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...