![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2649](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452649.webp)
15 Power Control Measurement
Meas
where Xi is a data point value, X is the arithmetic mean of the data point values for the specified region
(s), and n is the number of data points in the specified region(s).
where |Xi| is the magnitude of an I/Q pair, X is the mean of the magnitudes for the specified region(s), and
n is the number of data points in the specified region(s).
•
PPHase - returns the x,y pairs of both rms power (dBm) and arithmetic mean phase (radian) for every
specified region and frequency offset (Hz). The number of pairs is defined by the specified number of
regions. This parameter can be used for I/Q vector (n=0) in Waveform (time domain) measurement and
all parameters are specified by data point in PPHase.
The rms power of the specified region may be expressed as:
Power = 10 x log [10 x (RMS I/Q value)] + 10.
The RMS I/Q value (peak volts) is:
where Xi is the complex value representation of an I/Q pair, Xi* its conjugate complex number, and n is
the number of I/Q pairs in the specified region.
The arithmetic mean phase of the specified region may be expressed as:
where Yi is the unwrapped phase of I/Q pair with applying frequency correction and n is the number of
I/Q pairs in the specified region.
The frequency correction is made by the frequency offset calculated by the arithmetic mean of every
specified region’s frequency offset. Each frequency offset is calculated by the least square method
against the unwrapped phase of I/Q pair.
Sample Trace Data - Constant Envelope
(See below for explanation of variables.)
W-CDMA & HSPA Measurement Applications Reference
2649
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...