![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2442](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452442.webp)
14 QPSK EVM Measurement
Save
the file will be overwritten. Using the C: drive is strongly discouraged, since it runs the risk of being
overwritten during an instrument software upgrade.
While the save is being performed, the floppy icon appears briefly in the Meas bar.
File/Folder List
Enables you to navigate to the center of the dialog that contains the list of files and folders. Once here you
can get information about the file and use the tab keys to navigate to the other fields in the dialog, such as
Save In.
Save In
The Save In field shows the path to which the file will be saved and allows you to change the path using the
up and down arrow keys to navigate to other paths; the Enter key to open a directory; and the Backspace
key to go back one directory. The Save In field defaults to the default path for this type of file and
remembers the last path you used to save this type of file. There is no softkey for directly navigating to the
Save In field but you can use left tab to get here from the File/Folder List.
User specified paths are remembered when you leave and return to a Mode and are reset back to the
default using Restore Mode Defaults.
File Name
The File Name field is initially loaded with an automatically generated filename specific to the appropriate
Save Type. The automatically generated filename is guaranteed not to conflict with any filename currently
in the directory. You may replace or modify this filename using the File Name key. See the
documentation for more on the automatic file naming algorithm.
When you press the File Name key the analyzer displays the Alpha Editor.Use the knob to choose the
letter to add and the front-panel Enter key to add the letter to the file name. The BK character moves you
back and the FW character moves you forward in the filename. The Select key on the front panel generates
a space character. When you are done entering the filename press the Done softkey. This returns back to
the File Open dialog and menu, but does not cause the save to occur.
Save As Type
This field shows the file suffix for the type of file you have selected to save. For example, if you navigated
here while saving State, "Mode state (*.state)" is in the field. If you navigated here from saving Trace,
""Mode state (*.trace)" is in the field. If you navigated here while exporting a trace data file, "Trace Data
(*.csv)" is in the field. For some file types, there is more than one choice in the dropdown, which you can
select by using the up and down arrow keys and Enter.
Up One Level
This key corresponds to the icon of a folder with the up arrow that is in the tool bar of the dialog. When
pressed, it causes the file and folder list to navigate up one level in the directory structure. The Backspace
key does the same thing.
Create New Folder
This key corresponds to the icon of a folder with the "*" that is in the tool bar of the dialog. When pressed, a
new folder is created in the current directory with the name New Folder and you can enter a new folder
name using the Alpha Editor.
Cancel
2442
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...