Program description:
Flight phases
Application:
Typically for recording phases of fl ight with
increased motor speed, assuming that the
same switch is used to move between pha-
ses.
Time2
“Time2” records both the “Off” and the “On” ti-
mes of the associated switch, i. e. the timer
restarts every time the switch is operated,
and the counter is incremented by “1”.
You can stop any time count without opera-
ting the switch itself by pressing the
ESC
but-
ton. Operating the switch in turn increases the
counter by 1, and restarts the Time2 timer.
If you wish to read out the time memory using
the rotary control, you
must
fi rst halt the
Time2 timer by pressing the
ESC
button.
Application:
This timer would be used typically to record
the time required to complete fl ight tasks
which follow immediately after one another.
Pressing
CLEAR
at the basic display resets stopped
timers.
Note:
Please note: if you have programmed the “Auto ti-
mer reset” function in the »
Base setup model
« menu
(see page 64) to “yes”, then these timers are reset
when you switch the transmitter on.
“Switch time” column
When you switch between fl ight phases, it is advisab-
le to program a “soft” transition INTO (!) the next pha-
se; this is done by entering a transition time in this
column; the range available is 0 to 9.9 seconds. The
mx
-24s also allows you to set different transition ti-
mes for switching from any of phases 1 … 7 to, say,
phase 3, than for into Phase 1.
However, for safety reasons there is
ALWAYS
zero
delay when switching into the auto-rotation fl ight pha-
se. The arrow “
” in the “Transition time” column in-
dicates that a delay time can be selected OUT OF (!)
auto-rotation INTO (!) another phase.
After a brief press on the rotary control you can select
a transition time within the range 0 to 9.9 seconds in
the highlighted value fi eld.
(Pressing
CLEAR
= 0.0 s.)
Example:
Autorot
Phase 1
3.0s
Phase 2
1.0s
Phase 3
SEL
Autorot
2.0s
Normal
0.1s
SEL
-
Aerobat
+
+
SEL
–
Name
Fl.ph.Tim.
Sw. time
“Autorot”:
the set transition time
from
this phase
into any other
phase is 2.0 seconds. In
the reverse direction the transition time
is always 0.0 seconds.
“Phase 1”: the transition time
into
this phase
from
any
of the phases 2 … 7 is 3.0 seconds,
i. e. a smooth transition.
“Phase2”:
the transition time
into
this phase
from
any
of the phases 1 or 3 … 7 is 1.0 se-
conds.
Unequal transition times, as shown in our examp-
le, can be useful when switching between widely dif-
fering fl ight phases, such as between aerobatics and
normal fl ight.
Note:
The “transition time” set here applies uniformly to
all fl ight phase specifi c settings, and also to all mi-
xers activated in the »
Helicopter mixers
« menu; see
page 122. This avoids abrupt changes between pha-
se-specifi c mixers. However, if you wish individu-
al servos to be switched without delay, simply defi -
ne them accordingly in the »
Non-delayed channels
«
menu; see page 105.
Summary of Contents for mx-24s
Page 1: ...1...
Page 19: ...19 For your notes...
Page 35: ...35 For your notes...
Page 41: ...41 41 For your notes...
Page 57: ...57 For your notes...
Page 63: ...63 63 For your notes...
Page 69: ...69 69 For your notes...
Page 85: ...85 85 For your notes...
Page 99: ...99 For your notes...
Page 143: ...143 For your notes...
Page 191: ...191 For your notes...
Page 212: ...212 212 For your notes...
Page 213: ...213 213 For your notes...
Page 214: ...214 For your notes...
Page 216: ...216...