Checking fuel pressure
Check fuel pressure using the fuel
pressure kit supplied with the
Mathesis tester.
Remove the fuel delivery hose to the
tank (8).
Use the pressure hose (1). Connect
one end to tank delivery hose
connector (A) and the other end on
the delivery hose (8). This will create
a pressure take-up point (C).
Connect the transducer (3) to the
take-up point (C). The transducer will
convert the pressure reading into an
electric signal.
Connect the power cable (2) to the
middle RC 589 connector on the
Mathesis diagnostic tester and
connect connector (D) of the cable (2)
to the motorcycle's power socket (E).
Connect the analog input interface
cable (5) to the pressure transducer
(3) and to the Mathesis COM2 port.
Follow the instructions in the
Mathesis manual, in menu
“Pressure”, screen “Auxiliary”.
Maximum pressure must be
3
bar
(nominal pressure).
When through with the test, remove
the components of the pressure kit
and refit the delivery hose (8).
Controllo pressione
carburante
Per verificare la pressione carburante
utilizzare il kit pressione carburante in
dotazione allo strumento Mathesis.
Rimuovere il tubo mandata serbatoio
(8).
Utilizzando il tubo (1) pressione, colle-
garne un’estremità (A) al raccordo del
tubo mandata al serbatoio e l’altra (B)
sul tubo (8) mandata: in questo modo
si crea una presa (C) di pressione.
Alla presa (C) viene collegato il sen-
sore (3), per trasformare il segnale di
pressione in segnale elettrico.
Collegare il cavo alimentazione (2) alla
presa RC 589 (centrale) del Mathesis
e la presa (D) del cavo (2) alla presa (E)
di alimentazione del moto.
Collegare il cavo (5) di interfaccia per
ingresso analogico al sensore
pressione (3) e alla presa COM2 del
Mathesis.
Seguire la procedura indicata nel
manuale dello strumento, al menù
“Pressione” della schermata
“Ausiliari”.
La pressione massima deve essere
uguale a
3
bar (nominale).
Finita la prova, rimuovere i
componenti del kit pressione e
rimontare il tubo (8) mandata
serbatoio.
D
2
A
B
C
1
5
3
8
514.1.034.1A
F
D
E
2
COM2
RC589
514.1.034.1A
Summary of Contents for ST3 2004
Page 1: ...Manuale d officina Workshop manual Model Year 2004 St3 DUCATISPORTTOURING...
Page 13: ...A B C D E F G H L M N P Indice generale General summary 12 ST3 M Y 2004 edizione edition 00...
Page 14: ...A B C D E F G H L M N P Generalit 0 Description 0...
Page 28: ...A B C D E F G H L M N P Informazioni sul modello 0 Model specific information 0...
Page 32: ...A B C D E F G H L M N P Caratteristiche tecniche 0 Technical specification 0...
Page 80: ...A B C D E F G H L M N P Uso e manutenzione 0 Use and Maintenance operations 0...
Page 140: ...A B C D E F G H L M N P Vestizione 0 Fairing 0...
Page 168: ...N L H G F E D C B A P Comandi Dispositivi 0 Controls Devices 0...
Page 198: ...N L H G F E D C B A P Ruote Sospensioni Freni0 Wheels Suspensions Brakes 0...
Page 246: ...A B C D E F G H L M N P Mototelaio 0 Frame 0...
Page 280: ...A B C D E F G H L M N P Impianto di alimentazione Scarico 0 Fuel system Exhaust system 0...
Page 316: ...A B C D E F G H L M N P Impianto iniezione Accensione 0 Ignition injection system 1...
Page 358: ...A B C D E F G H L M N P Motore 0 Engine 1...
Page 552: ...A B C D E F G H L M N P Impianto elettrico 0 Electric system 0...
Page 620: ...A B C D E F G H L M N P Indice degli argomenti 0 Subject index 0...