Table 406: CVGAPC Group settings (advanced)
Name
Values (Range)
Unit
Step
Default
Description
MultPU_OC1
1.0 - 10.0
-
0.1
2.0
Multiplier for scaling the current setting
value for OC1
ResCrvType_OC1
Instantaneous
IEC Reset
ANSI reset
-
-
Instantaneous
Selection of reset curve type for OC1
tResetDef_OC1
0.00 - 6000.00
s
0.01
0.00
Reset time delay used in IEC Definite Time
curve OC1
P_OC1
0.001 - 10.000
-
0.001
0.020
Parameter P for customer programmable
curve for OC1
A_OC1
0.000 - 999.000
-
0.001
0.140
Parameter A for customer programmable
curve for OC1
B_OC1
0.000 - 99.000
-
0.001
0.000
Parameter B for customer programmable
curve for OC1
C_OC1
0.000 - 1.000
-
0.001
1.000
Parameter C for customer programmable
curve for OC1
PR_OC1
0.005 - 3.000
-
0.001
0.500
Parameter PR for customer programmable
curve for OC1
TR_OC1
0.005 - 600.000
-
0.001
13.500
Parameter TR for customer programmable
curve for OC1
CR_OC1
0.1 - 10.0
-
0.1
1.0
Parameter CR for customer programmable
curve for OC1
MultPU_OC2
1.0 - 10.0
-
0.1
2.0
Multiplier for scaling the current setting
value for OC2
ResCrvType_OC2
Instantaneous
IEC Reset
ANSI reset
-
-
Instantaneous
Selection of reset curve type for OC2
tResetDef_OC2
0.00 - 6000.00
s
0.01
0.00
Reset time delay used in IEC Definite Time
curve OC2
P_OC2
0.001 - 10.000
-
0.001
0.020
Parameter P for customer programmable
curve for OC2
A_OC2
0.000 - 999.000
-
0.001
0.140
Parameter A for customer programmable
curve for OC2
B_OC2
0.000 - 99.000
-
0.001
0.000
Parameter B for customer programmable
curve for OC2
C_OC2
0.000 - 1.000
-
0.001
1.000
Parameter C for customer programmable
curve for OC2
PR_OC2
0.005 - 3.000
-
0.001
0.500
Parameter PR for customer programmable
curve for OC2
TR_OC2
0.005 - 600.000
-
0.001
13.500
Parameter TR for customer programmable
curve for OC2
CR_OC2
0.1 - 10.0
-
0.1
1.0
Parameter CR for customer programmable
curve for OC2
tResetDef_UC2
0.00 - 6000.00
s
0.01
0.00
Reset time delay used in IEC Definite Time
curve UC2
ResCrvType_OV1
Instantaneous
Frozen timer
Linearly
decreased
-
-
Instantaneous
Selection of reset curve type for OV1
Table continues on next page
1MRK 502 066-UUS B
Section 11
Multipurpose protection
695
Technical manual
Summary of Contents for Relion 670 series
Page 1: ... RELION 670 SERIES Generator protection REG670 Version 2 1 ANSI Technical manual ...
Page 2: ......
Page 48: ...42 ...
Page 62: ...56 ...
Page 182: ...176 ...
Page 692: ...686 ...
Page 726: ...720 ...
Page 1014: ...1008 ...
Page 1242: ...1236 ...
Page 1362: ...1356 ...
Page 1386: ...1380 ...
Page 1422: ...1416 ...
Page 1431: ...1425 ...