Name
Values (Range)
Unit
Step
Default
Description
tTRCrv1
0.005 - 100.000
-
0.001
13.500
Parameter TR for customer programmable
curve for step 1
tCRCrv1
0.1 - 10.0
-
0.1
1.0
Parameter CR for customer programmable
curve for step 1
HarmBlock1
Disabled
Enabled
-
-
Disabled
Enable block of step 1 for harmonic
restraint
ResetTypeCrv2
Instantaneous
IEC Reset
ANSI reset
-
-
Instantaneous
Selection of reset curve type for step 2
tReset2
0.000 - 60.000
s
0.001
0.020
Constant reset time for step 2
tPCrv2
0.005 - 3.000
-
0.001
1.000
Parameter P for customer programmable
curve for step 2
tACrv2
0.005 - 200.000
-
0.001
13.500
Parameter A for customer programmable
curve for step 2
tBCrv2
0.00 - 20.00
-
0.01
0.00
Parameter B for customer programmable
curve for step 2
tCCrv2
0.1 - 10.0
-
0.1
1.0
Parameter C for customer programmable
curve for step 2
tPRCrv2
0.005 - 3.000
-
0.001
0.500
Parameter PR for customer programmable
curve for step 2
tTRCrv2
0.005 - 100.000
-
0.001
13.500
Parameter TR for customer programmable
curve for step 2
tCRCrv2
0.1 - 10.0
-
0.1
1.0
Parameter CR for customer programmable
curve for step 2
HarmBlock2
Disabled
Enabled
-
-
Disabled
Enable block of step 2 for harmonic
restraint
ResetTypeCrv3
Instantaneous
IEC Reset
ANSI reset
-
-
Instantaneous
Selection of reset curve type for step 3
tReset3
0.000 - 60.000
s
0.001
0.020
Constant reset time for step 3
tPCrv3
0.005 - 3.000
-
0.001
1.000
Parameter P for customer programmable
curve for step 3
tACrv3
0.005 - 200.000
-
0.001
13.500
Parameter A for customer programmable
curve for step 3
tBCrv3
0.00 - 20.00
-
0.01
0.00
Parameter B for customer programmable
curve for step 3
tCCrv3
0.1 - 10.0
-
0.1
1.0
Parameter C for customer programmable
curve for step 3
tPRCrv3
0.005 - 3.000
-
0.001
0.500
Parameter PR for customer programmable
curve for step 3
tTRCrv3
0.005 - 100.000
-
0.001
13.500
Parameter TR for customer programmable
curve for step 3
tCRCrv3
0.1 - 10.0
-
0.1
1.0
Parameter CR for customer programmable
curve for step 3
HarmBlock3
Disabled
Enabled
-
-
Disabled
Enable block of step 3 for harmonic
restraint
ResetTypeCrv4
Instantaneous
IEC Reset
ANSI reset
-
-
Instantaneous
Selection of reset curve type for step 4
Table continues on next page
1MRK 502 066-UUS B
Section 8
Current protection
457
Technical manual
Summary of Contents for Relion 670 series
Page 1: ... RELION 670 SERIES Generator protection REG670 Version 2 1 ANSI Technical manual ...
Page 2: ......
Page 48: ...42 ...
Page 62: ...56 ...
Page 182: ...176 ...
Page 692: ...686 ...
Page 726: ...720 ...
Page 1014: ...1008 ...
Page 1242: ...1236 ...
Page 1362: ...1356 ...
Page 1386: ...1380 ...
Page 1422: ...1416 ...
Page 1431: ...1425 ...