![NXP Semiconductors LPC84x Скачать руководство пользователя страница 292](http://html.mh-extra.com/html/nxp-semiconductors/lpc84x/lpc84x_user-manual_1721742292.webp)
UM11029
All information provided in this document is subject to legal disclaimers.
© NXP Semiconductors N.V. 2017. All rights reserved.
User manual
Rev. 1.0 — 16 June 2017
292 of 515
NXP Semiconductors
UM11029
Chapter 17: LPC84x USART0/1/2/3/4
9
CTSEN
CTS Enable. Determines whether CTS is used for flow
control. CTS can be from the input pin, or from the USART’s
own RTS if loopback mode is enabled.
0
0
No flow control. The transmitter does not receive any
automatic flow control signal.
1
Flow control enabled. The transmitter uses the CTS input
(or RTS output in loopback mode) for flow control purposes.
10
-
Reserved. Read value is undefined, only zero should be
written.
NA
11
SYNCEN
Selects synchronous or asynchronous operation.
0
0
Asynchronous mode is selected.
1
Synchronous mode is selected.
12
CLKPOL
Selects the clock polarity and sampling edge of received
data in synchronous mode.
0
0
Falling edge. Un_RXD is sampled on the falling edge of
SCLK.
1
Rising edge. Un_RXD is sampled on the rising edge of
SCLK.
13
-
Reserved. Read value is undefined, only zero should be
written.
NA
14
SYNCMST
Synchronous mode Master select.
0
0
Slave. When synchronous mode is enabled, the USART is a
slave.
1
Master. When synchronous mode is enabled, the USART is
a master.
15
LOOP
Selects data loopback mode.
0
0
Normal operation.
1
Loopback mode. This provides a mechanism to perform
diagnostic loopback testing for USART data. Serial data
from the transmitter (Un_TXD) is connected internally to
serial input of the receive (Un_RXD). Un_TXD and Un_RTS
activity will also appear on external pins if these functions
are configured to appear on device pins. The receiver RTS
signal is also looped back to CTS and performs flow control
if enabled by CTSEN.
17:16 -
Reserved. Read value is undefined, only zero should be
written.
NA
Table 323. USART Configuration register (CFG, address 0x4006 4000 (USART0), 0x4006 8000
(USART1), 0x4006 C000 (USART2), 0x4007 0000 (USART3), 0x4007 4000
(USART4)) bit description
…continued
Bit
Symbol
Value Description
Reset
Value