7.8.2 Active Alarms
The active alarm screen shows the current status of the system alarms. Pressing
Esc will return to the Main Menu
7.8.3 Configuration Menu
The configuration menu provides access to the controllers' configuration menu. It is
password
‐
protected. Contact your Versum Materials, Inc. Representative for your system
password. Chapter 8 Section 2 explains how to enter a password. Chapter 8 Section 6
describes the functionality of the Configuration Menu in detail.
The following options are available from the Configuration Menu:
Net Product Alarm Setpoints
Subcycle Parameters Leak
Test Parameters Digital
Inputs
Digital Outputs Analog
Inputs Analog Setup
Alarm Conditions Helium
Leak Check Password List
Historical Alarms Service
Functions System Setup
7.9
High Pressure Leak Test (HPLT)
HPLT is an optional piping configuration. The following section describes functionality of HPLT for
systems designed with the HPLT piping configuration.
7.9.1 Definitions
HPLT -
High Pressure Leak Test. This is the term used to describe the leak test function performed at
an elevated pressure on the CGA connection between a pigtail and cylinder. The control system
utilizes a pressure transducer to monitor for pressure decay and will indicate the presence of a leak.
Standard leak test -
this is the leak test function supplied with standard cabinets. It can be configured
as either inboard or outboard. Inboard is done with a helium spray at the CGA connection and a leak
detector pulling a vacuum through the leak test port. Outboard is done with a sniffer probe sensing at
the pressurized CGA connection.