Chapter 9 - Troubleshooting
_______________________________________________________________________________________________________________
MNL000303.doc
Revision 2
09/16/2016
SourceSystem TE11
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
9
-
8
9.5
No or Low Process Gas Flow
Possible Source of
Problem
Test
Solution
No or low process gas
pressure
See Section 9.4 above.
Process gas manual
isolation valve(s) closed or
partially closed
Check position of process gas
isolation valve(s).
Open fully.
Are any vent valves open?
Check position of all vent
valves.
Close any vent valves if
open.
Are process gas pneumatic
valves receiving sufficient
pressure to open?
Check if instrument supply is
adequate.
Adjust to 85-95 psig (5.9-
6.6 barg) if necessary.
9.6
Typical Alarms
This section assumes that all devices are calibrated and functioning according to the manufacturer's
specification. Contact your Versum Materials, Inc. Technical Representative or the manufacturer
should you need to obtain this information.
Before performing troubleshooting, review
the Safety section and read the warnings at
the beginning of this Chapter. If at any
time during troubleshooting, you are
unsure what to do next, DO NOT
CONTINUE. Contact Versum Materials,
Inc..
NOTE: Contact Versum Materials, Inc. if the alarm displayed on the screen does not
appear in this section.
NOTE: Contact Versum Materials, Inc. for the procedure for calibrating the
transducers.