Chapter 9 - Troubleshooting
_______________________________________________________________________________________________________________
MNL000303.doc
Revision 2
09/16/2016
SourceSystem TE11
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
9
-
6
Purge gas pressure
Check setting on pressure
Set pressure regulator to
Regulator set incorrectly
regulator.
Correct delivery pressure
80-90 psig (5.5-6.2 barg).
Purge gas pressure
Check input to controller,
Repair connections,
transducer (s)
Check connections and
repair or replace
malfunctioning
signal from pressure
transducer(s) as necessary
transducers.