background image

1

This appliance is tested and approved for use in winds up to 15 
mph. (25 km/hr.)  Do not use if wind is exceeding 15 mph. (25 
km/hr.) or damage will result.

Patio Plus

infrared patio heaters

Installation, Operating & Maintenance Instructions

This manual must be left with the purchaser/user of this appliance, and 

must remain with the appliance.

The installation of Patio Plus heaters must only be performed by licensed 
technicians trained and educated in the installation of this type of gas appliance.

WARNING: Read this manual completely before first installing or servicing this 
equipment.  Failure to read and fully understand this manual may result in an
improper installation, which could cause faulty operation of the heater, property 
damage, serious injury or death.  If you do not fully understand these instructions, 
contact your Patio Plus representative or the manufacturer prior to the 
commencement of installation, servicing or maintenance.  Easy Radiant Works 
accepts no responsibility for damages whatsoever resulting in improper installation 
of this heater.  Improper installation voids all warranties.  This manual must remain 
with the heater at all times.

For Your Safety

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other 
appliance.

Warning

Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage or 
death.  Read the complete installation manual and all warning labels on the appliance before installation or 
servicing this equipment.  This heater should be installed or serviced by a qualified, licensed gas technician.

For Your Safety

If you smell gas:

1.

Shut off gas to appliance.

2.

Extinguish any open flame.

3.

If odour continues, immediately call your gas supplier.

Consigned de Security

Ill is interdict d’utiliser des lequides inflammables ou degageant des vapeurs 
inflammables, a proximate de tout appareil fonctionnant au gaz.
Si vous sentez une odeaur de gaz:

1.

Fermer le gaz sur l’appareil.

2.

Eleinore toute flame ouverte.

3.

Si l’odeur persiste, contracter votre distributeur de gaz.

Summary of Contents for Patio Plus

Page 1: ...asy Radiant Works accepts no responsibility for damages whatsoever resulting in improper installation of this heater Improper installation voids all warranties This manual must remain with the heater...

Page 2: ...red to be wood compressed paper plant fibres or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retardant treated or p...

Page 3: ...osed Patios Enclosed patios must be large enough to meet the clearance to combustibles and ventilation requirements as provided for in all applicable codes For very small enclosed patios Patio Plus he...

Page 4: ...e kept clean 6 WARNING gas leaks are extremely dangerous and potentially explosive Do not use this product until a leak is repaired Easy Testing Procedure 1 Prepare a cup of soapy water 2 Attach regul...

Page 5: ...ing options PH 45 H LP Liquid Propane PH 50 H N Natural Gas Hanging Units PH 45 H R LP Liquid Propane PH 50 H R N Natural Gas Hanging Units with 24 volt remote switching option PH 45 IG LP Liquid Prop...

Page 6: ...heater and be sure to check all connections each time the cylinder is connected Always turn off the gas supply to the heater at the cylinder as soon as you are finished using the heater The L P cylin...

Page 7: ...the heater head hose assembly into the 3 post The top of the post can be identified by the 3 8 hole being at the top end Line up the 3 8 hole in the post with the 3 8 hole in the base of the heater he...

Page 8: ...ide the decorative cover onto the post from the bottom Place the post into the basemount T on the weighted base and slide the decorative cover down over the post retainer Connect gas supply to nipple...

Page 9: ...t Aline the 3 8 hole in the post with the 3 8 threaded hole in the base of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Slide the decorative cover onto the post from the bottom P...

Page 10: ...se of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Insert post into the ground support pipe and fasten with hardware provided Connect the gas supply to the nipple protruding from...

Page 11: ...ess cannot be created on the gas supply piping Step 3 Apply a suitably approved pipe sealant to the nipple protruding from the bottom of the hanging bracket Turn the heater head onto the nipple to ach...

Page 12: ...ank or other system After pilot is lit and it is mistakenly turned off the knob will be in an immovable position Wait 90 seconds and the thermocouple will cool and knob will be released to re light pi...

Page 13: ...Defective gas valve Dirty pilot Replace thermopile Replace gas valve Clean pilot Main Burner won t light No 24 Volt power to unit Low gas pressure Blockage in orifice Manual valve not in on position...

Page 14: ...tends a 3 YEAR warranty from the date of purchase to the original purchaser of this product against manufacturing defects in material and workmanship If this product fails to operate because of a manu...

Page 15: ...15...

Reviews: