1-26
SRW-5000/5500
SS-95 Board
SS-95 Board (Side A)
< Top View >
LED No.
Name
Color
Description
Normal state (Power: ON)
D400
CPU
Green
Blinks when the SYS1 CPU (IC101/SS-95 board) is operating normally.
Blinks
D401
—
Green
Lights when interruption processing of the SYS1 CPU (IC101/SS-95 board)
ON
is normal.
D402
ERR
Red
Lights when the SYS1 CPU (IC101/SS-95 board) is not operating normally.
OFF
D500
—
Green
Blinks when interruption processing of the SYS2 CPU (IC500/SS-95 board)
Blinks
is normal.
D501
—
Red
Lights when the SYS2 CPU (IC500/SS-95 board) is not operating normally.
OFF
D1028
LOG
Green
Lights when updating the servo log. Off when stopping.
ON
D1029
CPU
Green
Blinks when the servo CPU (IC801/SS-95 board) is operating normally.
Blinks
D1030
ERR
Red
Lights when servo errors have occurred.
OFF
Blinks when downloading the servo software.
VPR-79 Board
VPR-79 Board (Side A)
< Top View >
LED No.
Name
Color
Description
Normal state (Power: ON)
D2004
—
Green
Lights when the PLD3 (IC700/VPR-79 board) configuration.
OFF
D2005
—
Red
Factory use
OFF
D2006
—
Green
Blinks when the PLD1 (IC104/VPR-79 board) is operating normally.
Blinks
D2007
—
Red
Factory use
OFF
D2008
—
Green
Blinks when the PLD2 (IC910/VPR-79 board) is operating normally.
Blinks
D2008
D2007
D2006
D2005
D2004
A
B
C
D
E
F
G
H
J
K
1
2
3
4
5
D1030
D1029
D1028
D400
D500
D501
D401
D402
A
B
C
D
E
F
G
H
J
K
L
M
N
P
1
2
3
4
5