7-8
SRW-5000/5500
7-2-9. PB Equalizer Adjustment
m
.
This adjustment is required in both the 59.94 Hz mode
and the 50 Hz mode.
Adjust in the 59.94 Hz mode, and then adjust in the 50
Hz mode.
.
When this adjustment is not finished normally, perform
“6-2. Video Tracking Check”.
1. HDCAM SR Format
Tools
.
Alignment tape:
HR5-1B
.
Recording tape:
BCT-SR series
1.
Activate the ALT MAINTENANCE menu, and
display the RF ADJUST menu.
(HOME menu
→
[SFT]
+
[DIAG]
→
[SFT]
+
[F8]
→
[ALT]
→
[F7]
→
RF ADJUST menu)
(For the RF ADJUST menu, refer to Section 3-4-5.)
2.
Press the
[F1]
(FMT SEL) key several times to select
the HDCAM SR.
3.
Press the
[F4]
(EQULZR ADJ) key to display the
EQUALIZER ADJUST menu.
4.
Insert the alignment tape HR5-1B, then rewind it to the
tape beginning.
5.
To execute the automatic adjustments, press the
[F6]
(ALL CH ADJ) key then press the
[SET]
key.
.
After 12 minutes, the adjustments are completed,
then the message [Complete] is displayed.
Saving the Data
n
Do not save the adjustment data if any automatic adjust-
ment was not completed properly.
6.
Press the
[F1]
(NVRAM CTL) key to display the NV-
RAM CONTROL menu.
7.
Select the “SAVE ALL DATA” by pressing the cursor
keys, then press the
[F10]
(EXIT) key to saving data.
.
The message “Save Complete” will be displayed
when this data save is completed normally.
8.
Eject the alignment tape.
9.
Perform the next adjustment “2. HDCAM Format”.
2. HDCAM Format
Alignment tape:
HR5-1A
1.
Press the
[F2]
(FMT SEL) key several times to select
the HDCAM.
2.
Insert the alignment tape HR5-1A, then rewind it to
the tape beginning.
3.
To execute the automatic adjustments, press the
[F6]
(ALL CH ADJ) key then press the
[SET]
key.
.
After 2 minutes, the adjustments are completed, then
the message [Complete] is displayed.
Saving the Data
n
Do not save the adjustment data if any automatic adjust-
ment was not completed properly.
4.
Press the
[F1]
(NVRAM CTL) key to display the NV-
RAM CONTROL menu.
5.
Select the “SAVE ALL DATA” by pressing the cursor
keys, then press the
[F10]
(EXIT) key to saving data.
.
The message “Save Complete” will be displayed
when this data save is completed normally.
6.
Eject the alignment tape.
7.
In case of the option HKSR-5002 installed model,
perform the next adjustment “3. Digital BETACAM
Format”.
In case of the option HKSR-5002 is not installed, exit
the maintenance mode and perform “4. Adjustment in
the 50 Hz Mode”.