8-16
SRW-5000/5500
(2) HDCAM (SRW-5500 only)
1.
Activate the ALT MAINTENANCE menu, and
display the RF ADJUST menu.
(HOME menu
→
[SFT]
+
[DIAG]
→
[SFT]
+
[F8]
→
[ALT]
→
[F7]
→
RF ADJUST menu)
(For the RF ADJUST menu, refer to Section 3-4-5.)
2.
Press the
[F1]
(FMT SEL) key several times to select
the HDCAM.
3.
Press the
[F5]
(REC ADJ) key to display the REC
ADJUST menu.
4.
Insert the recording tape.
5.
To execute the automatic adjustment for the recording
current, press the
[F6]
(ALL CH ADJ) key then press
the
[SET]
key.
.
Message [Complete] will be displayed when this
adjustment is completed normally.
Saving the Data
n
Do not save the adjustment data if the automatic adjust-
ment was not completed properly.
6.
Press the
[F1]
(NVRAM CTL) key to display the NV-
RAM CONTROL menu.
7.
Select the “SAVE ALL DATA” by pressing the cursor
keys, then press the
[F10]
(EXIT) key to saving data.
.
The message “Save Complete” will be displayed
when this data save is completed normally.
8.
Eject the recording tape.
9.
Exit the maintenance mode.