5-57
SRW-5000/5500
S plate
assembly
Pins
Clamper
Harnesses
Tape cleaner
Tape end sensor
Harness (Tape end sensor)
(At the attaching)
PWH3
x
8
5-16-1. S Plate Assembly Replacement
Outline
Replacement
1.
Removing the S Plate Assembly
2.
Attaching the S Plate Assembly
Adjustment after Replacement
3.
Adjusting the Tape Running at Drum Entrance Side (Refer to Section 6-12-1.)
Preparation
1.
Turn the power off and disconnect the power cord.
2.
Remove the upper lid (front) assembly. (Refer to Section 1-3-1.)
3.
Remove the cassette compartment. (Refer to Section 1-5.)
4.
Open the AE-31H board. (Refer to figure in Section 5-1-2.)
Remove/Attach the S Plate Assembly
Removal
1. Removing the S Plate Assembly
(1) Disconnect the all harnesses from the
clamper of the S plate assembly .
(2) Disconnect the harness from the connector of
the tape end sensor.
(3) Remove the screw to remove the S plate
assembly.
c
As the edge of tape cleaner is sharp, use great
care to avoid a hand cut.