3-86
SRW-5000/5500
NVRAM
CTL
FMT
SEL
EXIT
All Adjust
[HDCAM-SR]
Press SET key.
RF ADJUST
NG
LIST
DIAG
F1
F2
F3
F4
ALT
F5
F6
F7
F8
F9
F10
3.
Cue up an alignment tape of the selected format to the tape beginning, and insert it.
m
.
The adjustment cannot be performed correctly with a non-specified cassette tape. Be sure to use the
following alignment tapes:
Selected format
HDCAM SR
HDCAM
Digital BETACAM
(HKSR-5002 installed model only)
Alignment tape
HR5-1B
HR5-1A
ZR5-1 (59.94 Hz mode)
ZR5-1P (50 Hz mode)
.
Pay attention to the transport start position of the tape so that the end and beginning of the tape are
not detected during adjustment. If the cassette is forcibly ejected during the automatic adjustment,
the adjustment is cancelled, its result is detected, and the display returns to the initial window. The
minimum tape amount required for a normal automatic adjustment is shown in the following table;
however, the tape amount increases or decreases if the adjustment is abnormal.
Menu
Upper level: Normal adjustment time
Lower level: Tape amount required (Transport mode)
RF ALL ADJUST
About 20 seconds/ALL
Adjustment time (PLAY)