5-18
SRW-5000/5500
5-4. Cleaning Roller and Video Head Cleaner Assembly
Replacement
Replace the cleaning roller every 3,000 hours of the drum rotating.
Replace the video head cleaner assembly every 6,000 hours of the drum rotating.
The cleaning roller is included in the video head cleaner assembly.
Outline
Replacement
1.
Remove the Harness (CN231/HN-268 Board)
2.
Remove the Video Head Cleaner Assembly
3.
Replace the Cleaning Roller
4.
Attach the Video Head Cleaner Assembly
5.
Confirming the Cleaning Roller Position
6.
Connect the Harness (CN231/HN-268 Board)
Adjustment after Replacement
7.
Confirm the Cleaning Solenoid Operation (Refer to Section 3-3-4.)
[F6]
(CLEAN PLG) of the ALT SERVO CHECK menu
Note
When the cleaning roller is replaced, it is recommended to replace the CR spacer at
the same time.
CR spacer: 3-182-765-02
Preparation
1.
Turn off the power.
2.
Remove the upper lid (front) assembly. (Refer to Section 1-3-1.)
3.
Remove the cassette compartment. (Refer to Section 1-5.)
4.
Open the AE-31H board. (Refer to the figure in Section 5-1-2.)