5-67
SRW-5000/5500
5-19. S Tension Regulator Assembly Replacement
Outline
Replacement
1.
Removing the S Plate Assembly (Refer to step 1 in Section 5-16-1.)
2.
Removing the S Tension Regulator Assembly
3.
Attaching the S Tension Regulator Assembly
4.
Reattaching the S Plate Assembly (Refer to step 2 in Section 5-16-1.)
Adjustment after Replacement
5.
Performing the Tension Offset Adjustment (Refer to Section 3-4-2.)
[F4]
(TENSN OFFSET) of the ALT SERVO ADJUST menu
6.
Adjusting the Tape Running (Refer to Sections 6-2 to 6-12.)
Note
The S tension regulator assembly comprises of precision components and is adjusted
strictly. When removing/installing, use extreme care to turn only screws specified.
Tools
.
Cleaning cloth:
3-184-527-01
.
Cleaning fluid:
9-919-573-01
Preparation
1.
Set the unit into the unthreading end mode. (Refer to step 2 in Section 5-1-2.)
2.
Turn the power off and disconnect the power cord.
2.
Remove the upper lid (front) assembly. (Refer to Section 1-3-1.)
3.
Remove the cassette compartment. (Refer to Section 1-5.)
Removal
1. Removing the S Plate Assembly
Remove the S plate assembly.
(Refer to step 1 in Section 5-16-1.)