8-17
SRW-5000/5500
8-5. Audio System/CUE System Adjustment
8-5-1. Adjustment Overview
The audio system of this VTR needs to adjust the analog audio system only. For the digital audio system,
any adjustment is not needed.
Tools
The following equipment (or equivalent) and fixtures are required for the audio system/CUE system
adjustments.
Audio analyzer
AUDIO PRECISION System One (SYS-22A)/Two (SYS-2022A)
Digital Voltmeter
ADVANTEST R6441B
CUE system
Oscilloscope
TEKTRONIX TDS3054B
CUE system
Frequency Counter
ADVANTEST R5362B
CUE system
Extension boards
EX-873
(Part No. A-8346-141-A)
Audio system
EX-949
(Part No. A-8347-714-A)
CUE system
Shorting clip (1 pc)
CUE system
Cleaning tape
BCT-HD12CL
(Separately available)
CUE system
Alignment tape
HR5-1A
(Part No. 8-960-076-01)
CUE system