3-56
SRW-5000/5500
EXIT
LCD GAIN ADJUST
Press numerical keys to adjust.
CH1(Blue) :0x80 0x00
CH2(Green):0x80 => 0x00
CH3(Red) :0x80 0x00
Press F9 key to save.
OTHERS CHECK
GAIN
ALL
GAIN
CH1
DE-
FAULT
GAIN
CH2
GAIN
CH3
SAVE
DIAG
F1
F2
F3
F4
ALT
F5
F6
F7
F8
F9
F10
SYSTEM
SCAN
SYSTEM MENU
1080/59.94i 422 YPbPr
[F1]SYSTEM LINE 1080
[F2]SYSTEM SCAN MODE Interlace
[F3]SYSTEM FRAME 29.97Hz
[F4]SYSTEM SIGNAL MODE 422
[F6]FRAME CONVERT 1080/59.94i
[F7]ACTIVE LINE 1080
[F8]CANCEL [F9]Exec of Reset VTR Sys
(STOP & STANDBY OFF/EJECT)
SYSTEM
LINE
SYSTEM
SCAN
SYSTEM
SIGNAL
FRAME
CNVERT
ACTIVE
LINE
CANCEL
EXEC
EXIT
SYSTEM
FREQ
422 YPbPr
444 RGB
DIAG
F1
F2
F3
ALT
F5
F6
F7
F8
F9
F10
F4
SYSTEM
SCAN
SYSTEM MENU
1080/59.94i 422 YPbPr
[F1]SYSTEM LINE 1080
[F2]SYSTEM SCAN MODE Interlace
[F3]SYSTEM FRAME 29.97Hz
[F4]SYSTEM SIGNAL MODE 422
[F6]FRAME CONVERT 1080/59.94i
[F7]ACTIVE LINE 1080
[F8]CANCEL [F9]Exec of Reset VTR Sys
(STOP & STANDBY OFF/EJECT)
SYSTEM
LINE
SYSTEM
SCAN
SYSTEM
SIGNAL
FRAME
CNVERT
ACTIVE
LINE
CANCEL EXEC
EXIT
SYSTEM
FREQ
F9
DIAG
F1
F2
F3
F4
ALT
F5
F6
F7
F8
F10
[F9]
(SYSTEM MENU) Key (SRW-5000)
Sets the operation mode of this unit.
n
The selectable systems differ according to the VTR
settings or option boards.
The unselectable system setting items are shaded.
Execution Procedure
1.
Press the
[F9]
(SYSTEM MENU) key to display the
SYSTEM menu.
2.
Press the
[F4]
(SYSTEM SIGNAL) key several times
for setting to the 4:2:2 or 4:4:4.
m
.
The 4:4:4 can be selected when the option HKSR-
5003 is installed.
.
Each setting item can also be selected using the
[(]
/
[)]
key or the MULTI CONTROL knob.
[F8]
(LCD GAIN) Key
Performs the gain adjustment of the color display.
Execution Procedure
1.
On the OTHERS CHECK menu, press the
[F8]
(LCD
GAIN) key to display the GAIN ADJUST menu.
2.
To perform the gain adjustments for all channels in
one operation.
.
Press the
[F1]
(GAIN ALL) key
To perform the gain adjustment for a specified chan-
nel:
.
Press the
[(]
/
[)]
key, or
[F2]
(GAIN CH1),
[F3]
(GAIN CH2), or
[F4]
(GAIN CH3) key to select a
channel to execute its gain adjustment.
3.
Enter a gain adjustment value in hexadecimal, using
numeric keys. (0x00 to 0xff)
.
To enter the values A to F, press the numeric keys 0
to 5 while pressing the
[SFT]
(SHIFT) key respec-
tively.
To return the gain adjustment value to the initial value,
press the
[F8]
(DE-FAULT) key.
n
To change the adjustment value and save it to the NV-
RAM in one operation, set the value using the MULTI
CONTROL knob.
Clockwise (
2
):
The data value increases.
Counterclockwise (
3
): The data value decreases.
4.
Press the
[F9]
(SAVE) key
.
The gain value is changed and saved onto the NV-
RAM.
5.
Press the
[F10]
(EXIT) key to return to the OTHERS