![Rohde & Schwarz R&S UPP User Manual Download Page 870](http://html.mh-extra.com/html/rohde-and-schwarz/rands-upp/rands-upp_user-manual_1477869870.webp)
Cascading
R&S
®
UPP
854
User Manual 1411.1055.32 ─ 10
8.4
Configuration of a Cascade
8.4.1
Configuration Using CASCADE Button
A cascade is configured once. The instruments each "remember" their respective role
(Master, Slave#) after being switched off and retain their state until they are explicitly
reset and reconfigured.
The individual instruments are always configured using two elements on the front of
the R&S
UPP: the "CASCADE/LAN RESET" button and the associated status LED.
When cabling a cascade, it is already implicitly defined which instrument will assume
the role of master and which instruments can function as slaves.
Each R&S
UPP that detects a clock signal at its "CLOCK IN" BNC socket on the rear
of the instrument automatically assumes the role of a "standalone slave", whereas
each instrument without a reference clock signal initially functions as a "standalone
device".
Only R&S
UPP800 instruments (audio analyzer, 8 channels) with installed software
option R&S
UPP
‑
K800 can assume the role of a master device.
8.4.1.1
Configuration of Master Device
The programming routine using the "CASCADE/LAN RESET" button is visualized
using a constellation diagram. A flashing signal sequence at the "CASCADE LED"
informs the user of the respective instrument state. For a list of the states with the cor-
responding signal sequences, see
Chapter 8.4.1.4, "State Coding of Slave Device"
Configuration of a Cascade
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...