![Rohde & Schwarz R&S UPP User Manual Download Page 545](http://html.mh-extra.com/html/rohde-and-schwarz/rands-upp/rands-upp_user-manual_1477869545.webp)
Instrument Functions
R&S
®
UPP
529
User Manual 1411.1055.32 ─ 10
Example:
In the sweep subsystem, "y-source" is set to "Funct Ch1".
In the Analyzer panel, RMS has been set as measurement function for which dBV has
been selected as the unit in the Function Config panel.
The dBV display unit for the RMS measurement function can be transferred to the Dis-
play panel which is indicated by the "Unit
Fnct
Track" checkboxes.
Example:
For the additional measurement function Waveform, there is no individually assigned
unit that may be set in a Config panel. Thus, no unit can be transferred from the ana-
lyzer for the Waveform graphics subsystem and the checkboxes for "Unit
Fnct
Track"
are not offered here.
Available in the graphics subsystems
Sweep, FFT, Bar Graph
Curve, Spectrum and Bar Graph Display