![Rohde & Schwarz R&S UPP User Manual Download Page 415](http://html.mh-extra.com/html/rohde-and-schwarz/rands-upp/rands-upp_user-manual_1477869415.webp)
Instrument Functions
R&S
®
UPP
399
User Manual 1411.1055.32 ─ 10
IEC 60268 applies the measured intermodulation products to the double upper fre-
quency; IEC 60118 applies them to the single upper frequency only. The results
according to IEC 60268 are therefore approx. 6
dB better than the results according to
IEC 60118.
"d2 (IEC 268)"
Measurement of the 2nd-order intermodulation product relative to the
double
amplitude at the upper frequency (acc. to IEC 60268):
2
1
2
2
2
lg
20
f
f
f
U
U
dB
d
"d3 (IEC 268)"
Measurement of the 3rd-order intermodulation products referenced to
the
double
amplitude at the upper frequency (acc. to IEC 60268):
2
2
1
2
1
2
2
3
2
lg
20
f
f
f
f
f
U
U
U
dB
d
Figure 5-11: DFD-d3 measurement in accordance with IEC 60268