Instrument Functions
R&S
®
UPP
542
User Manual 1411.1055.32 ─ 10
This enables limit lines or limit curves to be shifted according to the parameters in the
subsequent parameter fields "Parallel" and "Symmetrical".
If the Limit Shift function is enabled without activating limit monitoring, the subsequent
parameter fields should be regarded as default settings.
Available in the graphics subsystems
Sweep, FFT, Waveform, Bar Graph
Remote command:
Parallel
This enables limit lines or limit curves to be parallel shifted.
In this way limit curves derived from a "golden unit", for example, can be adapted very
easily to new circumstances
The limit lines, which were determined using -100
dBV and -150
dBV, are to be paral-
lel shifted by a value of 25
dBV to -75
dBV and -125
dBV.
Available in the graphics subsystems
Sweep, FFT, Waveform, Bar Graph
Remote command:
DISPlay:SWEep<n2>:A:LIMShift:PARallel
DISPlay:SWEep<n2>:B:LIMShift:PARallel
Symmetrical
This enables a tolerance band formed from two limit lines or limit curves to be made
broader or narrower
In this way a tolerance band derived from a "golden unit", for example, can be very
easily narrowed or broadened.
Curve, Spectrum and Bar Graph Display
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...