Remote Control - Fundamentals
R&S
®
UPP
673
User Manual 1411.1055.32 ─ 10
Bit No. Meaning
6
1 = The channel in question is underranged; the measurement result is inaccurate
and no longer in line with the specifications of the R&S
UPP.
The associated summary bit is in the STATus:QUEStionable register bit 2
Ch7
5
Ch6
4
Ch5
3
Ch4
2
Ch3
1
Ch2
0
Ch1
6.8.9
STATus:QUEStionable:OVERrange Register
This register only contains overrange information concerning the individual channels of
multichannel operation. It can be read by the query
STATus:QUEStionable:OVERrange:CONDition?
or
STATus:QUEStionable:OVERrange[:EVENt]?
.
Reading the EVENt part deletes its content!
Table 6-7: Meaning of bits in STATus:QUEStionable:OVERrange register
Bit No. Meaning
15
Slave 8
For cascading, signals with a '1' which slave has identified an overrange.
14
Slave 7
13
Slave 6
12
Slave 5
11
Slave 4
10
Slave 3
9
Slave 2
8
Slave 1
7
Ch8
0 = The channel in question is not overranged.
1 = The channel in question is overranged. If the measurement result of an over-
ranged channel is requested with the
SENSx:DATAy?
command, the value
"3.40282038" (represents NaN = Not a Number) is returned.
The associated summary bit is in the STATus:QUEStionable register bit 1
6
Ch7
5
Ch6
4
Ch5
3
Ch4
2
Ch3
Status Reporting System
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...