Center frequency
Defines the normal center frequency of the signal. The allowed range of values for the
center frequency depends on the frequency span.
span > 0: span
min
/2 ≤ f
center
≤ f
max
– span
min
/2
f
max
and span
min
are specified in the data sheet.
Remote command:
Center Frequency Stepsize
Defines the step size of the center frequency. The step size can be coupled to the
demodulation bandwidth, or it can be manually set to a fixed value.
"0.1 * Demod
BW"
Sets the step size for the center frequency to 10 % of the demodula-
tion bandwidth.
This is the default setting.
"0.5 * Demod
BW"
Sets the step size for the center frequency to 50 % of the demodula-
tion bandwidth.
"X * Demod
BW"
Sets the step size for the center frequency to a manually defined fac-
tor of the demodulation bandwidth. The "X-Factor" defines the per-
centage of the demodulation bandwidth.
Values between 1 and 100 % in steps of 1 % are allowed. The default
setting is 10 %.
"= Center"
Sets the step size to the value of the center frequency and removes
the coupling of the step size to the demodulation bandwidth. The
used value is indicated in the "Value" field.