![Rohde & Schwarz FSW Series User Manual Download Page 256](http://html.mh-extra.com/html/rohde-and-schwarz/fsw-series/fsw-series_user-manual_1477844256.webp)
Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
256
User Manual 1173.9240.02 ─ 17
Parameters:
<Time>
0 s to measurement time
*RST:
0 s
Example:
ADEM:PM:RPO 500us
Sets the position where the phase to 0 rad setting to 500 µs.
Usage:
SCPI confirmed
Manual operation:
See
"Zero Phase Reference Position (PM Time Domain only)"
[SENSe:]ADEMod:SQUelch[:STATe]
<State>
This command activates the squelch function, i.e. if the signal falls below a defined
threshold (see
data is automatically set to 0.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
DEM:SQU ON
Signals below the level threshold are squelched.
Manual operation:
See
[SENSe:]ADEMod:SQUelch:LEVel
<Threshold>
This command defines the level threshold below which the demodulated data is set to
0 if squelching is enabled (see
Parameters:
<Threshold>
numeric value
The absolute threshold level
Range:
-150 dBm to 30 dBm
*RST:
-40 dBm
Example:
DEM:SQU:LEV -80
If the signal drops below -80 dBm, the demodulated data is set
to 0.
Manual operation:
See
11.4.8.2
Time Domain Zoom Settings
Using the time domain zoom, the demodulated data for a particular time span is extrac-
ted and displayed in more detail.
Configuring the Measurement