Configuration
R&S
®
FSW-K7
124
User Manual 1173.9240.02 ─ 17
5.9.2 Analog Demodulation Output Settings
The demodulated signal in time domain results can be output to the IF/VIDEO/DEMOD
output connector on the rear panel of the R&S
FSW.
Output is not possible if the Digital Baseband Interface (R&S
FSW-B17) is active.
The following settings and functions are available to configure the output in the Analog
Demodulation application. They can be configured via the INPUT/OUTPUT key, in the
"Output" dialog box, in the "Analog Demod" tab.
Note that the audio frequency (AF) filter settings used for demodulation also apply to
the online output (see
on page 113). However, a maximum of
two high pass, low pass or deemphasis filters can be active at the same time if analog
demodulation output is active.
Online Demodulation Output State
............................................................................. 124
Online Demodulation Output State
Enables or disables online demodulation output. If enabled, the demodulated audio fre-
quencies are output to the IF/VIDEO/DEMOD output connector on the rear panel of the
R&S
FSW and, optionally, to the PHONES connector on the front panel (see
Remote command:
Output Selection
Selects the result display whose results are output. Only time domain results can be
selected. All currently active time domain result displays are listed.
Output Settings