Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
188
User Manual 1173.9240.02 ─ 17
[SENSe:]MIXer:HARMonic:BAND:PRESet
This command restores the preset frequency ranges for the selected standard wave-
guide band.
Note:
Changes to the band and mixer settings are maintained even after using the
PRESET function. Use this command to restore the predefined band ranges.
Example:
MIX:HARM:BAND:PRES
Presets the selected waveguide band.
Usage:
Event
Manual operation:
See
[SENSe:]MIXer:HARMonic:BAND[:VALue]
<Band>
This command selects the external mixer band. The query returns the currently
selected band.
This command is only available if the external mixer is active (see
Parameters:
<Band>
KA | Q | U | V | E | W | F | D | G | Y | J | USER
Standard waveguide band or user-defined band.
Manual operation:
See
Table 11-2: Frequency ranges for pre-defined bands
Band
Frequency start [GHz]
Frequency stop [GHz]
KA (A) *)
26.5
40.0
Q
33.0
50.0
U
40.0
60.0
V
50.0
75.0
E
60.0
90.0
W
75.0
110.0
F
90.0
140.0
D
110.0
170.0
G
140.0
220.0
J
220.0
325.0
Y
325.0
500.0
USER
32.18
(default)
68.22
(default)
*)
The band formerly referred to as "A" is now named "KA".
Configuring the Measurement