Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
288
User Manual 1173.9240.02 ─ 17
LAYout:WINDow<n>:ADD?
<Direction>,<WindowType>
This command adds a measurement window to the display. Note that with this com-
mand, the suffix <n> determines the existing window next to which the new window is
added, as opposed to
, for which the existing window is
defined by a parameter.
To replace an existing window, use the
This command is always used as a query so that you immediately obtain the name of
the new window as a result.
Parameters:
<Direction>
LEFT | RIGHt | ABOVe | BELow
<WindowType>
Type of measurement window you want to add.
See
on page 284 for a list of availa-
ble window types.
Return values:
<NewWindowName> When adding a new window, the command returns its name (by
default the same as its number) as a result.
Example:
LAY:WIND1:ADD? LEFT,MTAB
Result:
'2'
Adds a new window named '2' with a marker table to the left of
window 1.
Usage:
Query only
LAYout:WINDow<n>:IDENtify?
This command queries the
name
of a particular display window (indicated by the <n>
suffix).
Note
: to query the
index
of a particular window, use the
command.
Return values:
<WindowName>
String containing the name of a window.
In the default state, the name of the window is its index.
Usage:
Query only
LAYout:WINDow<n>:REMove
This command removes the window specified by the suffix <n> from the display.
The result of this command is identical to the
command.
Usage:
Event