Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
270
User Manual 1173.9240.02 ─ 17
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
SENS:ADJ:SCAL:Y:AUTO ON
Manual operation:
See
11.4.10 Configuring Standard Traces
Useful commands for trace configuration described elsewhere
●
●
Remote commands exclusive to trace configuration
DISPlay[:WINDow<n>]:TRACe<t>:MODE
.........................................................................270
DISPlay[:WINDow<n>]:TRACe<t>:MODE:HCONtinuous
....................................................271
DISPlay[:WINDow<n>]:TRACe<t>:SELect
........................................................................272
DISPlay[:WINDow<n>]:TRACe<t>[:STATe]
.......................................................................272
[SENSe:]ADEMod:AM[:ABSolute][:TDOMain][:TYPE]
........................................................ 272
[SENSe:]ADEMod:AM:RELative[:TDOMain][:TYPE]
.......................................................... 272
[SENSe:]ADEMod:AM:RELative:AFSPectrum[:TYPE]
........................................................272
[SENSe:]ADEMod:FM[:TDOMain][:TYPE]
.........................................................................272
[SENSe:]ADEMod:FM:AFSPectrum[:TYPE]
...................................................................... 272
[SENSe:]ADEMod:PM[:TDOMain][:TYPE]
........................................................................ 272
[SENSe:]ADEMod:PM:AFSPectrum[:TYPE]
......................................................................273
[SENSe:]ADEMod:SPECtrum[:TYPE]
...............................................................................273
............................................................................................. 274
..................................................................................275
..........................................................................................275
[SENSe:][WINDow<n>:]DETector<trace>[:FUNCtion]
........................................................ 275
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]:AUTO
.....................................................276
DISPlay[:WINDow<n>]:TRACe<t>:MODE
<Mode>
This command selects the trace mode.
In case of max hold, min hold or average trace mode, you can set the number of single
measurements with
. Note that synchronization to the end of
the measurement is possible only in single sweep mode.
In the Analog Demodulation application when you configure the traces for a window
with a specific evaluation (e.g. AM time domain), the traces in all windows with the
same evaluation are configured identically.
Configuring the Measurement