Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
210
User Manual 1173.9240.02 ─ 17
Query parameters:
<Type>
The power sensor type, e.g. "NRP-Z81".
<Interface>
Currently not evaluated
Return values:
<Placeholder>
Currently not used
<Type>
Detected power sensor type, e.g. "NRP-Z81".
<Interface>
Interface the power sensor is connected to; always "USB"
<SerialNo>
Serial number of the power sensor assigned to the specified
index
Example:
SYST:COMM:RDEV:PMET2:DEF '','NRP-Z81','',
'123456'
Assigns the power sensor with the serial number '123456' to the
configuration "Power Sensor 2".
SYST:COMM:RDEV:PMET2:DEF?
Queries the sensor assigned to "Power Sensor 2".
Result:
'','NRP-Z81','USB','123456'
The NRP-Z81 power sensor with the serial number '123456' is
assigned to the "Power Sensor 2".
Manual operation:
See
Configuring Power Sensor Measurements
CALibration:PMETer<p>:ZERO:AUTO ONCE
...................................................................210
CALCulate<n>:PMETer<p>:RELative[:MAGNitude]
........................................................... 211
CALCulate<n>:PMETer<p>:RELative[:MAGNitude]:AUTO ONCE
....................................... 211
CALCulate<n>:PMETer<p>:RELative:STATe
....................................................................212
[SENSe:]PMETer<p>:DCYCle[:STATe]
............................................................................ 212
[SENSe:]PMETer<p>:DCYCle:VALue
.............................................................................. 213
...................................................................................213
[SENSe:]PMETer<p>:FREQuency:LINK
...........................................................................213
.......................................................................................... 214
[SENSe:]PMETer<p>:MTIMe:AVERage:COUNt
................................................................ 214
[SENSe:]PMETer<p>:MTIMe:AVERage[:STATe]
...............................................................215
[SENSe:]PMETer<p>:ROFFset[:STATe]
...........................................................................215
.........................................................................................215
[SENSe:]PMETer<p>:UPDate[:STATe]
............................................................................ 216
......................................................................................... 216
............................................................................... 216
CALibration:PMETer<p>:ZERO:AUTO ONCE
This commands starts to zero the power sensor.
Configuring the Measurement