Configuration
R&S
®
FSW-K7
50
User Manual 1173.9240.02 ─ 17
5 Configuration
Analog demodulation measurements require a special application on the R&S
FSW,
which you activate using the MODE key on the front panel.
When you activate an Analog Demodulation application the first time, a set of parame-
ters is passed on from the currently active application (see
tings for Analog Demodulation"
on page 50). After initial setup, the parameters for
the measurement channel are stored upon exiting and restored upon re-entering the
channel. Thus, you can switch between applications quickly and easily.
When you activate the Analog Demodulation application, a Analog Demodulation mea-
surement for the input signal is started automatically with the default configuration. It
can be configured in the Analog Demodulation "Overview" dialog box, which is dis-
played when you select the "Overview" softkey from any menu.
The main configuration settings and dialog boxes are also available via the "Analog
Demod" menu which is displayed when you press the MEAS CONFIG key.
The remote commands required to perform these tasks are described in
"Remote Commands for Analog Demodulation Measurements"
Predefined settings
For commonly performed measurements, standard setup files are provided for quick
and easy configuration. Simply load an existing standard settings file and, if necessary,
adapt the measurement settings to your specific requirements.
For an overview of predefined standards and settings see
Default Settings for Analog Demodulation
.............................................................. 50
Configuration According to Digital Standards
......................................................... 51
...........................................................................................53
....................................................................................55
.............................................................................................. 94
........................................................................................... 106
................................................................................................ 126
5.1 Default Settings for Analog Demodulation
When you activate the Analog Demodulation application the first time, a set of parame-
ters is passed on from the currently active application:
●
center frequency and frequency offset
●
reference level and reference level offset
Default Settings for Analog Demodulation