13.4 Control Room Speaker Solo and Mute Controls
An individual Solo and Mute is provided for each speaker output feed.
The SOLO and CUT switches are labeled as follows:
•
LEFT: Left front Control Room monitor
•
CNTR (Center): Center front Control Room monitor
•
RIGHT: Right front Control Room monitor
•
SUR L (Surround Left): Left rear Control Room monitor
•
SUR R (Surround Right): Right rear Control Room monitor
•
LFE (Low Frequency Effects): Subwoofer Control Room monitor
•
A: A Control Room monitor
•
B: B Control Room monitor
Control Room CUT switches are linked to the Control Room Monitor source selectors. The CUT
switches will activate automatically depending on the selected Control Room Monitor source. If a
stereo source is selected the CNTR, SUR L, SUR R, LFE, A, and B monitor feeds will be cut. If a
surround source is selected, the needed speaker feed will be uncut.
CONTROL ROOM PRESET LEVEL ADJUST trim-pots: Sets the level of each speaker output feed
for the C/R CAL (Control Room Calibrate) switch
13.5 Control Room Monitor System Selection (CONTROL ROOM)
The Vision console provides support for three (3) complete 7.1 surround Control Room
monitoring systems. The Left and Right speakers for the active system are used for stereo
monitoring.
The Front and Rear speaker feeds may be summed to mono independently.
The Front and Rear speakers may be reversed (Flipped) Front to Rear, Rear to Front.
The CONTROL ROOM section of the center section
contains the primary controls for the three Control
Room Monitor systems:
•
MAIN SPKR (Main Speakers): Main Control
Room monitor system
•
ALT 1 (Alternate 1): Alternate Control Room
monitor system #1 (mid-fields)
•
ALT 2 (Alternate 2): Alternate Control Room
monitor system #2 (near-fields)
ALT 1 and 2 have trim controls for matching levels
between the three systems.
A calibrated Control Room monitor level (85 dB) may
be set for film work and other purposes. The preset
level is activated by engaging the C/R CAL (Control
Room Calibrate) button.
Monitor CUT and a DIM control with variable level may
be applied to the active Control Room Monitor system.
SOLO: Solos the selected
speaker feed
•
Defeats speaker
feeds that are not
soloed
•
Illuminates in yellow
when engaged
CUT: Cuts the selected
speaker feed
•
Illuminates in red
when engaged