Solo: Groups functions just like Solo: Normal (see above), except that the muting is restricted
to whatever group that contains the MUTE that was pressed.
Pressing a MUTE that is not in a group will solo within the ungrouped channels.
Solo: Groups only looks at mute groups, not fader, insert or switch groups.
Changes to mutes made with Solo: Groups engaged are not recorded to automation.
Refer to section 26.7.3 ACM Main Menu for details regarding the use of the ACM menu items.
11.4
Solo Bus Access Patch Points
Solo: Groups: Replaces the function of the MUTE buttons
with an additive solo-in-place function within a current
group
•
To activate the Solo: Groups mode:
o
Select Solo: Groups from the Solo submenu
in the ACM
o
Click the Solo: Groups button in the Global
Functions window in the PC software
•
When Solo: Normal is engaged:
o
“SG” will appear VCP main display
o
The Solo: Groups button in the Global
Functions window will illuminate in yellow
STEREO/SOLO SUM BUS ACCESS IN: Stereo and Solo
Summing Bus Access Inputs
•
Normalled to the Stereo A, B, C, and SOLO busses
•
Signals patched into the STEREO SUM BUS ACCESS
IN patch points will be added the bus before the
Stereo and Solo ACAs