Command reference
R&S
®
ZNA
1239
User Manual 1178.6462.02 ─ 20
Suffix:
<Port>
.
Port number
Parameters:
<Loss>
Loss value
Default unit: dB
Options:
R&S
ZNA-K8
[SENSe:]CONVerter<Port>:LOPort
<Local>, <LocalIndex>
Defines the source for the LO In port of converter <Port>.
Suffix:
<Port>
.
Converter number = VNA port number
Parameters:
<Local>
NONE | RLO | PORT | GENerator | SPLitter
The port type, further specified by its index <LocalIndex>
NONE
No LO source defined
RLO
The optional LO Out port at the rear panel of the R&S
ZNA
PORT
A VNA port
GENerator
An external generator port
SPLitter
A splitter is used to distribute the original LO signal to the LO In
ports of the involved converters
<LocalIndex>
The port index, if required.
For NONe and RLO the index is ignored.
Options:
R&S
ZNA-K8
Manual operation:
See
[SENSe:]CONVerter<Port>:RFLoss
<Loss>
Defines the cable loss at the source port or converter <Port>.
Suffix:
<Port>
.
Converter port number (= physical VNA port number)
Parameters:
<Loss>
Loss value
Default unit: dB
Options:
R&S
ZNA-K8
Manual operation:
See