Command reference
R&S
®
ZNA
915
User Manual 1178.6462.02 ─ 20
CALCulate<Chn>:EYE:MASK:SHAPe:BOTTom:STATe
<Boolean>
CALCulate<Chn>:EYE:MASK:SHAPe:POLYgon:STATe
<Boolean>
CALCulate<Chn>:EYE:MASK:SHAPe:TOP:STATe
<Boolean>
Activates/deactivates the respective area in the eye mask of the related eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
The eye mask test is enabled/disabled using
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
*RST:
OFF
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:MASK:SHAPe:BOTTom:HORizontal
<Width>
CALCulate<Chn>:EYE:MASK:SHAPe:TOP:HORizontal
<Width>
Defines the width of the bottom/top rectangle in the eye mask of the related eye dia-
gram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Use
CALCulate<Chn>:EYE:MASK:SHAPe:BOTTom:STATe
or
to activate or deactivate the area in the eye mask.
The eye mask test is enabled/disabled using
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Width>
Default unit: s
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:MASK:SHAPe:BOTTom:VERTical
<Offset>
CALCulate<Chn>:EYE:MASK:SHAPe:TOP:VERTical
<Offset>
Defines the offset of the bottom/top rectangle in the mask of the related eye diagram.
The offset is specified relative to the vertical center of the eye mask (see
CALCulate<Chn>:EYE:MASK:CENTer:VERTical
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
SCPI command reference