[SENSe<Ch>:]CORRection:OFFSet<PhyPt>:MAGNitude
.................................................1582
[SENSe<Ch>:]FREQuency:CONVersion:MIXer:IFFixed
................................................... 1582
[SENSe<Ch>:]FREQuency:CONVersion:MIXer:LOFixed
..................................................1583
[SENSe<Ch>:]FREQuency:CONVersion:MIXer:RFFixed
..................................................1583
[SENSe<Ch>:]FREQuency:IMODulation:TTOutput
..........................................................1584
.................................................................................1584
[SENSe<Ch>:]SEGMent<Seg>:CLEar
........................................................................... 1584
[SENSe<Ch>:]SEGMent<Seg>:OVERlap
....................................................................... 1585
.................................................................................... 1585
..................................................................................... 1585
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect[:ACQuire]
......................................1587
TRACe[:DATA][:RESPonse][:ALL]?
................................................................................ 1588
....................................................................................1589
CALCulate<Chn>:LIMit:CONTrol:DOMain
<SweepType>
Deletes the existing limit line and (re-)defines the physical units of the stimulus values
of the limit line. The units of the response values and the scaling of the y-axis can be
defined via
CALCulate<Ch>:LIMit:RDOMain:...
Suffix:
<Chn>
.
Channel number used to identify the active trace.
Setting parameters:
<SweepType>
FLIN | FLOG | FSEG | FSINgle | TLIN | TLOG | PLIN | PLOG |
PSINgle
Keywords for the units of the stimulus values. The selected unit
must be compatible with the sweep type (
); otherwise the limit line can not be displayed
and no limit check is possible.
The parameters form three groups: FLIN, FLOG, FSEG, and
FSINgle select frequency units for the limit line. TLIN and TLOG
select time units, PLIN, PLOG and PSINgle select power units.
*RST:
FLIN
Default unit: Hz (for FLIN, FLOG, FSEG, FSINGle); s (for TLIN,
TLOG), dBm (for PLIN, PLOG, PSINgle).
Example:
SWE:TYPE POW
Select a power sweep.
CALC:LIM:CONT:DOM PLIN
Delete all existing limit line segments and select level units for
the limit line of the active trace.
CALC:LIM:CONT -20, -10
Define a limit line segment in the stimulus range between -20
dBm and -10 dBm.
Usage:
Setting only
R&S ZVR/ZVABT compatible commands