Command reference
R&S
®
ZNA
955
User Manual 1178.6462.02 ─ 20
CALCulate:FMODel:SFD...
Commands for PacketMicro's
Smart Fixture De-embedding
www.packetmicro.com/Products/sfd-tool.html
CALCulate:FMODel:SFD<Ph_pt>:AUTO
.......................................................................... 955
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure
....................................................... 955
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure:FILename
........................................955
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure:FILename:CLEar
..............................956
CALCulate:FMODel:SFD<Ph_pt>:COUPon[:STATe]
.......................................................... 956
CALCulate:FMODel:SFD<Ph_pt>:COUPon:TYPE
.............................................................956
CALCulate:FMODel:SFD<Ph_pt>:DIFFcfg
........................................................................957
CALCulate:FMODel:SFD<Ph_pt>:DUT:MEASure
.............................................................. 957
CALCulate:FMODel:SFD<Ph_pt>:DUT:MEASure:FILename
...............................................957
CALCulate:FMODel:SFD<Ph_pt>:DUT:MEASure:FILename:CLEar
.................................... 957
CALCulate:FMODel:SFD<Ph_pt>:PRESet
........................................................................958
CALCulate:FMODel:SFD<Ph_pt>:DUT[:STATe]
.................................................................958
CALCulate:FMODel:SFD<Ph_pt>:RUN:RUN
.................................................................... 958
CALCulate:FMODel:SFD<Ph_pt>:RUN[:STATe]
................................................................ 959
CALCulate:FMODel:SFD<Ph_pt>:TOTaldiffcfg
..................................................................959
CALCulate:FMODel:SFD<Ph_pt>:AUTO
<Boolean>
Defines whether the SFD tool shall perform automatic impedance adjustments.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<Boolean>
Manual operation:
See
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure
For a fixture modeling with the SFD tool, this command starts the measurement of the
coupon at the active ports (see
CALCulate:FMODel:SFD<Ph_pt>:COUPon[:
).
The coupon type can be selected using
.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Usage:
Event
Manual operation:
See
"Measure / Measure Open / Measure Short"
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure:FILename
<String>
For a fixture modeling with the SFD tool, this command loads the coupon properties
from a Touchstone file.
SCPI command reference