Command reference
R&S
®
ZNA
1041
User Manual 1178.6462.02 ─ 20
Parameters:
<Boolean>
ON | OFF – reference range limit lines on or off.
*RST:
OFF
Options:
R&S
ZNA-K1
Manual operation:
See
CALCulate<Chn>:STATistics:RDOMain:USER:STARt
<Start>
CALCulate<Chn>:STATistics:RDOMain:USER:STOP
<Value>
Defines the start/stop value of the range selected via
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Stop>
Start/stop value of the related range
Default unit: Hz
Options:
R&S
ZNA-K1
Manual operation:
See
CALCulate<Chn>:STATistics:PRATio[:STATe]
<Boolean>
Displays or hides the power ratio statistics in the diagram area of spectrum analysis
channel
<Chn>
's active trace.
Use
CALCulate<Chn>:STATistics:PRATio:RESult?
to query the results.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
ON | OFF – info field on or off.
*RST:
OFF
Options:
R&S
ZNA-K1
Manual operation:
See
CALCulate<Chn>:STATistics:PRATio:RESult?
Returns the power ratio staticstics (three comma-separated numeric values) of a spec-
trum analysis trace:
●
Power density in reference range
(see
CALCulate<Chn>:STATistics:RDOMain:USER
)
●
Power density in evaluation range
(see
CALCulate<Chn>:STATistics:DOMain:USER
)
●
Power ratio (trace value vs. reference range)
SCPI command reference