Command reference
R&S
®
ZNA
1441
User Manual 1178.6462.02 ─ 20
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:CFACtor
........................................1448
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:FLATness
..................................... 1448
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:METHod
....................................... 1449
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:RRECeiver
....................................1450
SOURce:POWer:CORRection:COLLect:VNETworks
....................................................... 1450
SOURce<Ch>:POWer<PhyPt>:CORRection:DATA:PARameter<Wv>:COUNt?
SOURce<Ch>:POWer<PhyPt>:CORRection:DEFault
...................................................... 1451
SOURce<Ch>:POWer<PhyPt>:CORRection:FAST
..........................................................1452
SOURce<Ch>:POWer<PhyPt>:CORRection:GENerator<Gen>[:STATe]
............................ 1452
SOURce<Ch>:POWer:CORRection:IMODulation:METHod
.............................................. 1453
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:LTONe[:ACQuire]
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:UTONe[:ACQuire]
SOURce<Ch>:POWer<PhyPt>:CORRection:NREadings
................................................. 1455
SOURce<Ch>:POWer<PhyPt>:CORRection:OSOurces[:STATe]
.......................................1455
SOURce:POWer:CORRection:PPOWer
......................................................................... 1456
SOURce:POWer:CORRection:PPOWer:PATTenuation
.....................................................1456
SOURce<Ch>:POWer<PhyPt>:CORRection:PSELect
..................................................... 1456
SOURce<Ch>:POWer<PhyPt>:CORRection:STATe
........................................................ 1457
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient[:STATe]
....................................1457
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:CALibration
..............................1458
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:COUNt?
...................................1459
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DEFine<ListNo>
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DELete<ListNo>:ALL
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DELete<ListNo>[:DUMMy]
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:FEED
...................................... 1461
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:INSert<ListNo>
SOURce:POWer:CORRection:PMETer:ID
<PowerMeter>
Selects an external power meter for the scalar source power calibration (flatness cali-
bration).
Note:
The command cannot be used unless a power meter is connected via GPIB bus,
USB or LAN interface and configured in the "External Power Meters" dialog.
Parameters:
<PowerMeter>
Number of external power meter. The parameters UP, DOWN,
MIN, MAX are not available for this command.
Range:
1 to number of configured external power meters
*RST:
The power meter selection is not changed by a
reset of the analyzer.
Example:
See
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect[:
Manual operation:
See
SOURce:POWer<PhyPt>:CORRection:SLEVeling:DELete
Removes the (global) leveling dataseet of port <PhyPt>.
SCPI command reference