GUI reference
R&S
®
ZNA
738
User Manual 1178.6462.02 ─ 20
Advanced Settings...
If the active trace is an eye diagram, the "Advanced Settings..." button opens the
that allows in-depth configuration of the simulated digital sig-
nal generator and receiver.
Display Measurements
If the active trace is an eye diagram, the "Display Measurements" button in the
softtool tab toggles the display of the eye diagram results.
The available results depend on the selected
:
●
For NRZ modulated generator signals the result display comprises two separate
info fields for "Basic" and "Time" results (see
default they are stacked below each other, however, they can be moved independ-
ently like any other info field.
Figure 5-53: Eye Diagram Results (NRZ Modulation)
●
For PAM modulation types only a reduced set of "Basic" results is available.
Figure 5-54: Eye Diagram Results (PAM Modulations)
For a description of the result values see
Remote command:
CALCulate<Chn>:EYE:MEASurement:STATe
CALCulate<Chn>:EYE:MEASurement:DATA?
Measurements...
If the active trace is an eye diagram, the "Measurements..." button brings up a dialog
which allows to select and configure the eye measurements to be displayed (if
is enabled).
Applic softtool