Command reference
R&S
®
ZNA
1468
User Manual 1178.6462.02 ─ 20
Manual operation:
See
SOURce<Ch>:POWer<Pt>:EATTenuation
<Manual ElSourceAtt>
Defines the electronic source attenuation at port <Pt> in channel <Ch>. This setting will
only take effect if
SOURce<Ch>:POWer<Pt>:EATTenuation:MODE
MANual
.
Suffix:
<Ch>
.
Channel number
<Pt>
Port number
Parameters:
<Manual
ElSourceAtt>
Supported attenuation values are 0
dB, 20
dB, and 40
dB.
Default unit: dB
Manual operation:
See
SOURce<Ch>:POWer<Pt>:EATTenuation:MODE
<ElSourceAttMode>
Defines how the electronic source attenuation of port <Pt> is selected in channel
<Ch>.
Suffix:
<Ch>
.
Channel number
<Pt>
Port number
Parameters:
<ElSourceAttMode> AUTO | MANual
AUTO
The firmware selects the suitable electronic attenuation value.
MANual
You can select the electronic attenuation value using
SOURce<Ch>:POWer<Pt>:EATTenuation
Manual operation:
See
SOURce<Ch>:POWer<PhyPt>:GENerator<Gen>:OFFSet
<Offset>, <Mode>
Defines the power of an external generator or its power offset relative to the channel
power (
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate][:AMPLitude]
).
Suffix:
<Ch>
.
Channel number
<PhyPt>
Test port number of the analyzer. This suffix is ignored; the gen-
erator is selected via
<Gen>
.
<Gen>
Generator number
SCPI command reference