Command reference
R&S
®
ZNA
1514
User Manual 1178.6462.02 ─ 20
This setting applies to the analyzer GUI and to the remote commands
*RST
and
is set to
ON
.
Parameters:
<Boolean>
OFF (0)
A factory preset is performed.
ON (1)
A user-defined preset is performed, if the setup file selected
using
erwise, a factory preset is performed.
Example:
SYST:PRES:USER:NAME 'C:\Users\Public\Documents
\Rohde-Schwarz\ZNA\RecallSets\Setup_2.znxml'
Select a setup file for the user-defined preset.
SYST:PRES:USER ON
Enable the user-defined preset.
SYSTem:PRESet:REMote ON
Align
*RST
(and
SYSTem:PRESet
) to the user-defined preset.
*RST
Perform the user-defined preset.
Manual operation:
See
SYSTem:PRESet:USER:CAL
<PresetUserCal>
Selects a calibration from the calibration pool that shall be restored during a user-
defined preset.
The corresponding cal group file (
<PresetUserCal>.cal
) must be available in the
cal pool directory
C:\Users\Public\Documents\Rohde-Schwarz\ZNA\Calibration\Data\
.
Parameters:
<PresetUserCal>
Name of the cal group (i.e. the name of the cal group file without
path and extension).
Use the empty string to restore the default behavior (no preset
user cal).
Example:
MMEMORY:STORE:CORRection 1, 'Refl1
Trans123.cal'
Adds the active user calibration to the memory pool
SYSTem:PRESet:USER:CAL 'Refl1 Trans123'
Sets the newly created cal pool member as the preset user cal.
SYSTem:PRESet:USER:CAL?
Queries for the preset user cal. Returns
'Refl1 Trans123'
SYSTem:PRESet:USER:CAL ''
Restores the default behaviour of the instrument: no preset user
cal.
Manual operation:
See
SCPI command reference