Command reference
R&S
®
ZNA
1512
User Manual 1178.6462.02 ─ 20
Manual operation:
See
SYSTem:PRESet[:DUMMy]
Performs a preset, whose scope is defined using the
mand. The
command determines whether a factory
preset or a user-defined preset is performed.
Example:
SYST:PRES:SCOP SING
Define the scope of a preset: the active recall set is reset only.
SYST:PRES
Reset the parameters of the current recall set to their factory
defaults.
Manual operation:
See
SYSTem:PRESet:MODE
<PresetMode>
Allows you to select between different preset modes.
GLOBal and RFOFf presets can only be performed from the analyzer GUI. FILE pre-
sets can also be performed via remote commands, if
is set to
ON
.
Parameters:
<PresetMode>
NORMal | FILE | GLOBal | RFOFf
NORMal
Factory preset
FILE
GLOBal
Factory GUI reset + reset RF connection configuration
between VNA and external devices
RFOFf
Factory
Manual operation:
See
"Normal / RF Off / Normal, GUI, Ext Setup / <File Name>"
SYSTem:PRESet:REMote[:STATe]
<Boolean>
Defines the behavior of the preset commands
*RST
Parameters:
<Boolean>
OFF (0)
*RST
and
SYSTem:PRESet
perform a factory preset.