Command reference
R&S
®
ZNA
988
User Manual 1178.6462.02 ─ 20
Parameters:
<Boolean>
ON - show the bandfilter search results. If no bandfilter search
has been initiated before (
BFILter
), nothing is displayed.
OFF - hide the bandfilter search results.
*RST:
OFF
Example:
See
CALCulate<Chn>:MARKer<Mk>:BWIDth
Manual operation:
See
CALCulate<Chn>:MARKer:SEARch:BFILter:RESult[:STATe]:AREA
<HorizontalPos>, <VerticalPos>
Moves the bandfilter search info field for the active trace
<Chn>
to one of nine prede-
fined positions in the active diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<HorizontalPos>
LEFT | MID | RIGHt
Horizontal position
<VerticalPos>
TOP | MID | BOTTom
Vertical position
Example:
See
CALCulate<Chn>:MARKer<Mk>:BWIDth
Manual operation:
See
CALCulate<Chn>:MARKer<Mk>:AOFF
Removes all markers from all traces of the active recall set. The removed markers
remember their properties (stimulus value, format, delta mode, number) when they are
restored (
CALCulate<Chn>:MARKer<Mk>[:STATe]
ON
). The marker properties are
definitely lost if the associated trace is deleted.
Suffix:
<Chn>
.
Channel number used to identify the active trace. If unspecified
the numeric suffix is set to 1.
<Mk>
This numeric suffix is ignored and may be set to any value.
Example:
Suppose that the active recall set contains an active trace no. 1.
CALC:MARK1 ON; MARK2 ON
Create markers 1 and 2 and assign them to the trace no. 1.
CALC:MARK:AOFF
Remove both markers.
Usage:
Event
Manual operation:
See
SCPI command reference