Command reference
R&S
®
ZNA
1367
User Manual 1178.6462.02 ─ 20
Suffix:
<Ch>
.
Channel number
Parameters:
<Pulse Duty Cycle>
A value between 0 and 100.
Default unit: percent
Options:
R&S
ZNA<Freq>-B4<Pt> or R&S
ZNA-B91
Manual operation:
See
[SENSe<Ch>:]PULSe:FXDCycle[:STATe]
<Boolean>
Defines whether the analyzer firmware shall enforce a fixed duty cycle for all pulse
generators.
Suffix:
<Ch>
.
Channel number
Parameters:
<Boolean>
ON (1)
Fixed duty cycle for all pulse generators in channel <Ch>.
The pulses are defined using
.
OFF (0)
The generator-specific pulses are defined using
*RST:
OFF
Options:
R&S
ZNA<Freq>-B4<Pt> or R&S
ZNA-B91
Manual operation:
See
[SENSe<Ch>:]PULSe:GENerator:PERiod
<Period for the generated pulses>
Suffix:
<Ch>
.
Parameters:
<Period for the
generated pulses>
[SENSe<Ch>:]PULSe:GENerator:SOURce
<source for pulse generator>
Suffix:
<Ch>
.
Parameters:
<source for pulse
generator>
EXTA | EXTB | EXTC | EXTD | INT
SCPI command reference