Original Instructions
July 25, 2023
p/n: 208795
Rev. H
208795
Q5X with Dual Discrete Outputs and IO-
Link Quick Start Guide
•
•
•
Product Description for the Q5X Dual Discrete
This guide is designed to help you set up and install the
Q5X Laser Measurement Sensor
. For complete information on programming, perfor
mance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at
. Search for p/
n
208794
to view the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices.
WARNING:
Do not use this device for personnel protection
Using this device for personnel protection could result in serious injury or death.
This device does not include the selfchecking redundant circuitry necessary to allow its use in personnel safe
ty applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output
condition.
Features
The
Q5X Laser Measurement Sensor
has three major features.
Q5X
Features
1
2
3
Display and Indicators
The display is a 4digit, 7segment LED. Run mode is the primary view displayed.
For 2-pt, BGS, FGS, and DYN TEACH modes, the display shows the current distance to the target in centimeters. For Dual TEACH mode,
the display shows the percentage matched to the taught reference surface. A display value of
999P
indicates the sensor has not been
taught.
Display in Run Mode
STB DYN FGS BGS
1
2
Output Indicator
On: The output is on
Off: The output is off
Stability Indicator (STB)
On—Stable signal within the specified sensing range
Flashing—Marginal signal (low excess gain), the target is out
side the limits of the specified sensing range, or a multiple
peak condition exists
Off—No target is detected within the specified sensing range
Active TEACH Indicators (DYN, FGS, and BGS)
DYN, FGS, and BGS all off—Twopoint TEACH mode select
ed (default)
DYN on—Dynamic TEACH mode selected
FGS on—Foreground suppression TEACH mode selected
BGS on—Background suppression TEACH mode selected
DYN, FGS, and BGS all on—Dual TEACH mode selected
Two output indicators (amber)
1.
Display
2.
Buttons
3.
Stability Indicator (STB—Green)
1.
◦
◦
◦
Active TEACH Indicators
DYN—Dynamic (Amber)
FGS—Foreground Suppression (Amber)
BGS—Background Suppression (Amber)
2.
© Banner Engineering Corp.