9 Servo Parameter Objects
9 - 50
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
•
If the motor speed exceeds the set value during an immediate stop resulting from an error, an
Overspeed 2 Error (Error No. 26.1) will occur.
•
The overspeed detection level setting is 1.2 times the maximum motor speed if this object is set to 0.
•
This object should normally be set to 0. The setting should be changed only when it is necessary to
lower the overspeed detection level.
For details, refer to 12-3-2 Immediate Stop Operation at Errors on page 12-11.
•
Set the initialization time after turning ON the power supply to the standard 1.5 seconds plus the
specified value.
Refer to 3-1-9 Control Output Details on page 3-12 for the details at power ON.
•
Set the compensation gain for disturbance force.
For details, refer to 11-8 Disturbance Observer Function on page 11-28.
•
Set the filter time constant for disturbance force compensation.
For details, refer to 11-8 Disturbance Observer Function on page 11-28.
3615 hex
Overspeed Detection Level Setting at Immediate Stop
Setting
range
0 to 20,000
Unit
mm/s
Default
setting
0
Data
attribute
A
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible
3618 hex
Power Supply ON Initialization Time
Setting
range
0 to 100
Unit
0.1 s
Default
setting
0
Data
attribute
R
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible
3623 hex
Disturbance Force Compensation Gain
Setting
range
–100 to 100
Unit
%
Default
setting
0
Data
attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible
3624 hex
Disturbance Observer Filter Setting
Setting
range
10 to 2,500
Unit
0.01 ms
Default
setting
53
Data
attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible
A l l
A l l
csp
csp
Содержание R88D-KN01H-ECT-L
Страница 136: ...3 Specifications 3 60 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 190: ...4 System Design 4 54 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 208: ...5 EtherCAT Communications 5 18 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 226: ...6 Basic Control Functions 6 18 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 268: ...7 Applied Functions 7 42 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 276: ...8 Safety Function 8 8 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 616: ...Appendices A 170 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 617: ...Index 1 I G5 series Linear Motors Servo Drives With Built in EtherCAT Communications Index...
Страница 624: ......
Страница 625: ......